Product Code : 11
DIAL SIZE
150 mm (6”)
ACCURACY
+ - 1.5 % of range span
MOUNTING
Direct with bottom entry. Flush panel with back entry/bottom entry
MAX.STATIC PRESSURE
10 to 100 bar/kg/cm2
SENSING ELEMENT
Diaphragm of S S 316 upto 2.5 bar/kg/cm2. Above 2.5 bar/kg/cm2 upto 25 bar/kg/cm2 Diaphragm is of alloy steel.
RANGES
0-0.6, 1, 1.6, 2, 2.5,4, 6, 10, 16, 25, bar/kg/cm2.
STANDARD RANGES
0.400, 600, 1000, 1600, 2500, 4000 and 6000 mmwc
CHAMBER MATERIAL
AISI 304
STANDARD FITMENT
Over range relief value. External zero adjustment.
ACCESSORIES AVAILABLE
CONNECTION
¼” NPT (female) standard other, connection are available with adaptor.